Functional sample SMD foil sensor Na (Sodium) – Na-01

€45.00*

Content: 5 Stück (€9.00* / 1 Stück)
Product number: 1020
Product information "Functional sample SMD foil sensor Na (Sodium) – Na-01"
The SMD foil sodium electrode Na-01 is designed for electrochemical, potentiometric determination of Na+ in liquid or moist samples when combined with a reference electrode. The readings are taken by measuring the open circuit potential/voltage between both electrodes via high resistivity voltage measurement electronics (see example circuit below). Potential (E) and sodium concentration have a linear relationship in the operating range of 100 µM to 1 M. The sodium concentration of an unknown analyte solution can be calculated using the pre-determined slope and an offset E0 value, which can be determined by measuring the potential in a calibration solution of known sodium concentration. Once used, the sensor must be kept hydrated for further application and must not allowed to dry out.

Datasheet:
Datasheet_addsensors_SMD_Na01_eng.pdf

Design / User Manual:
Design-Setup-Guide.pdf (addsensors.com)

Zubehör

Functional sample SMD foil sensor peripheral layout for electrochemical 1-parameter potentiostatic measurement
Peripheral layout for electrochemical sensors, consisting of 2 electrodes for potentiometric measurement, connection for addSensors evaluation unit or ZIF Pad Area for adaptation with FPC connector.

€15.00*
Functional sample SMD foil sensor peripheral layout for electrochemical 1-parameter measurement
Peripheral layout for electrochemical sensors, consisting of 2 electrodes for potentiometric measurement, suitable for e.g. SPE Connector (2 mm banana) from PalmSens.Note: Do not use for longer than 36 hours in liquid media, as the coating will then peel off!

€5.00*

Ähnlich

Functional sample SMD foil sensor reference electrode - RE-01
The SMD foil reference electrode RE-01 is designed for electrochemical, potentiometric measurements in liquid or moist samples when combined with a second, ionselective sensing electrode.The readings are taken by measuring the open circuit potential/voltage between both electrodes via high resistivity voltage measurement electronics.Once used, the sensor must be kept hydrated for further application and must not allowed to dry out.Datasheet:Datasheet_addsensors_SMD_RE01_eng.pdfDesign / User Manual:Design-Setup-Guide.pdf (addsensors.com)

Content: 5 Stück (€9.00* / 1 Stück)

€45.00*